The Effect of Partial Substitution of Cement with Coal Fly Ash on the Physical and Mechanical Properties of Cellular Lightweight Concrete (CLC)

dc.contributor.authorBianita, Yunda Aliefia
dc.date.accessioned2026-11-16T07:40:47Z
dc.date.issued2026
dc.description.abstractThe construction industry faces major challenges in adopting sustainable practices, as cement production accounts for around 8% of global CO2 emissions. Cellular Lightweight Concrete (CLC) bricks offer a lightweight, energy-efficient wall material, yet their production still relies heavily on cement as the primary binder. Class F fly ash, an industrial by-product from the PLTU Sumsel–8 power plant, possesses pozzolanic properties that make it a promising partial cement substitute. This study aims to determine the effect of fly ash substitution on the physical and mechanical properties of CLC bricks, to identify the optimum percentage among variations of 0%, 10%, 20%, 30%, and 40%, and to analyse the correlation between bulk density and compressive strength. The research was conducted experimentally at the Construction Materials Laboratory of Universitas Islam Indonesia. Block specimens measuring 60×20×10 cm were cast for each variation, then cut according to SNI 8640:2018 into specimens for compressive strength (10×10×10 cm), density, and water absorption (20×20×10 cm) testing. Testing was performed at 28 days of age using a Universal Testing Machine (UTM), referring to SNI 8640:2018. The results show a non-monotonic trend, with the 20% fly ash variation as the optimum point, yielding the highest oven-dry density (824,55 kg/m³), the lowest water absorption (17,07%), and the highest compressive strength (0,6045 MPa). At 30% and 40%, all properties declined due to additional voids from unreacted fly ash. However, all compressive strength values remained below the SNI 8640:2018 minimum requirement (2 MPa), indicating the need for further development. A positive correlation was found between oven-dry density and compressive strength of CLC bricks, with a coefficient of determination R2 = 0,9425.
dc.identifier.urihttps://repository.uii.ac.id/handle/123456789/67816
dc.publisherUniversitas Islam Indonesia
dc.subjectCLC Bricks
dc.subjectFly Ash
dc.subjectOven-Dry Density
dc.subjectCompressive Strength
dc.titleThe Effect of Partial Substitution of Cement with Coal Fly Ash on the Physical and Mechanical Properties of Cellular Lightweight Concrete (CLC)
dc.typeThesis